1.
Hypertension ; 80(5): 1110-1116, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36912176

RESUMEN

BACKGROUND: To identify and summarize the global research literature on validation of automated noninvasive blood pressure measurement devices (BPMDs) with upper arm cuff, develop a repository of validated BPMDs in compliance with the 2020 World Health Organization technical specifications, and identify challenges and gaps in evidence base on validated BPMDs. METHODS: A scoping review was conducted. Primary research validating BPMDs complying with the 2020 World Health Organization technical specifications (ie, semiautomated/automated noninvasive devices with upper arm cuff), published in English between January 2000 and December 2021, was included. We searched MEDLINE, Web of Science, Scopus, EMBASE, CINAHL, CENTRAL, ProQuest and the dabl website. RESULTS: We included 269 studies validating 251 BPMDs across 89 manufacturers. Omron (29%), Microlife (10%), and A&D Company (8%) were the top 3 manufacturers. The 3 most frequently used validation protocols were the European Society of Hypertension-international protocol 2002 (27%), European Society of Hypertension-international protocol 2010 (25%), and modified British Hypertension Society protocol 1993 (16%), respectively. Nearly 45% of the validated BPMDs were intended for use in clinical settings, 38% were for home or self-measurement use, and 48% were for general adults. Most studies reported that BPMDs passed the validation criteria. There was inadequate reporting across studies, especially pertaining to validation settings. CONCLUSIONS: Most BPMDs fulfilled the validation criteria. However, there are considerable gaps in BPMD research in terms of geographical representation, including specific target populations and diseases/conditions, and a range of arm circumferences. Additionally, a potential strategy is required to accelerate the adoption of the Association for the Advancement of Medical Instrumentation (AAMI)/European Society of Hypertension/International Organization for Standardization Universal Standard (International Organization for Standardization 81060-2:2018) for BPMD validation.


Asunto(s)
Determinación de la Presión Sanguínea , Hipertensión , Adulto , Humanos , Presión Sanguínea , Determinación de la Presión Sanguínea/métodos , Esfigmomanometros , Organización Mundial de la Salud , Monitores de Presión Sanguínea
2.
Cancer ; 128 Suppl 4: 875-882, 2022 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-35133661

RESUMEN

The development and implementation of a multicancer early detection (MCED) test that is effective and affordable has the potential to change cancer care systems around the world. However, careful consideration is needed within the context of different health care settings (both low- and middle-income countries and high-income countries) to roll out an MCED test and promote equity in access.


Asunto(s)
Países en Desarrollo , Neoplasias , Detección Precoz del Cáncer , Humanos , Renta , Internacionalidad , Neoplasias/diagnóstico , Neoplasias/terapia
3.
J Infect Dis ; 226(3): 420-430, 2022 08 26.
Artículo en Inglés | MEDLINE | ID: mdl-32614451

RESUMEN

BACKGROUND: Hepatitis C virus (HCV) screening is critical to HCV elimination efforts. Simplified diagnostics are required for low-resource settings and difficult-to-reach populations. This retrospective study assessed performance of rapid diagnostic tests (RDTs) for detection of HCV antibodies. METHODS: Two lots of 13 RDTs were evaluated at 3 laboratories using archived plasma samples from 4 countries (Nigeria, Georgia, Cambodia, and Belgium). HCV status was determined using 3 reference tests according to a composite algorithm. Sensitivity and specificity were evaluated in HIV-infected and HIV-uninfected populations. Operational characteristics were also assessed. RESULTS: In total, 1710 samples met inclusion criteria. In HIV-uninfected samples (n = 384), the majority of RDTs had sensitivity ≥98% in 1 or both lots and most RDTs had specificity ≥99%. In HIV-infected samples (n = 264), specificity remained high but sensitivity was markedly lower than in HIV-uninfected samples; only 1 RDT reached >95%. The majority of HIV-infected samples for which sensitivity was low did not have detectable HCV viral load/core antigen. Interreader variability, lot-to-lot variability, and rate of invalid runs were low for all RDTs (<2%). CONCLUSIONS: HCV RDTs should be evaluated in the intended target population, as sensitivity can be impacted by population factors such as HIV status. CLINICAL TRIALS REGISTRATION: NCT04033887.


Asunto(s)
Infecciones por VIH , Hepatitis C , Humanos , Hepacivirus , Pruebas Diagnósticas de Rutina , Laboratorios , Estudios Retrospectivos , Hepatitis C/complicaciones , Hepatitis C/diagnóstico , Anticuerpos contra la Hepatitis C , Sensibilidad y Especificidad , Infecciones por VIH/epidemiología
4.
J Diabetes Sci Technol ; 16(1): 168-214, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34120487

RESUMEN

BACKGROUND: Conventional home blood glucose measurements require a sample of blood that is obtained by puncturing the skin at the fingertip. To avoid the pain associated with this procedure, there is high demand for medical products that allow glucose monitoring without blood sampling. In this review article, all such products are presented. METHODS: In order to identify such products, four different sources were used: (1) PubMed, (2) Google Patents, (3) Diabetes Technology Meeting Startup Showcase participants, and (4) experts in the field of glucose monitoring. The information obtained were filtered by using two inclusion criteria: (1) regulatory clearance, and/or (2) significant coverage in Google News starting in the year 2016, unless the article indicated that the product had been discontinued. The identified bloodless monitoring products were classified into three categories: (1) noninvasive optical, (2) noninvasive fluid sampling, and (3) minimally invasive devices. RESULTS: In total, 28 noninvasive optical, 6 noninvasive fluid sampling, and 31 minimally invasive glucose monitoring products were identified. Subsequently, these products were characterized according to their regulatory, technological, and consumer features. Products with regulatory clearance are described in greater detail according to their advantages and disadvantages, and with design images. CONCLUSIONS: Based on favorable technological features, consumer features, and other advantages, several bloodless products are commercially available and promise to enhance diabetes management. Paths for future products are discussed with an emphasis on understanding existing barriers related to both technical and non-technical issues.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus , Glucemia , Cuerpo Humano , Humanos , Tecnología
5.
J Clin Virol ; 137: 104783, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33711695

RESUMEN

INTRODUCTION: Dried blood spots (DBS) have potential to improve access to screening for antibodies to hepatitis C virus (HCV). However, although several studies on off-label use of DBS have been performed, to date no HCV antibody serology test is formally approved for use with DBS. This study evaluated the performance of the INNOTEST® HCV Ab IV enzyme immunoassay in paired DBS and plasma samples, to determine whether DBS may be added to the intended use. METHODS: Adults with no history of HCV treatment were prospectively enrolled from two sites in Ukraine. DBS were prepared from fingerstick whole blood (fDBS) and venous whole blood (vDBS) samples. Undiluted and serially diluted DBS and plasma samples were tested. RESULTS: Samples from 149 HCV positive and 151 HCV negative participants were included. Sensitivity and specificity of the INNOTEST® HCV Ab IV assay were both 100 % (95 % confidence intervals 95.7-100) for samples collected on fDBS or vDBS compared with plasma as the reference standard. In all undiluted samples, negative and positive percentage agreement and overall rate of agreement were 100 % between all sample types (Cohen's kappa coefficient of 1). In serially diluted samples, agreement was high (>95 %) between fDBS and vDBS, and as expected, positive percentage agreement between both DBS sample types and plasma was lower (>66 %). CONCLUSIONS: Performance of the INNOTEST® HCV Ab IV assay in DBS was acceptable, thus whole blood collected on DBS may represent an alternative sample type for this assay in settings where venous blood collection is not possible.


Asunto(s)
Hepacivirus , Hepatitis C , Adulto , Pruebas con Sangre Seca , Hepatitis C/diagnóstico , Anticuerpos contra la Hepatitis C , Humanos , Técnicas para Inmunoenzimas
6.
PLoS One ; 15(12): e0243040, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33270716

RESUMEN

BACKGROUND: This study evaluated performance of two hepatitis C virus (HCV) rapid diagnostic tests (RDTs) performed by intended users in resource-limited settings. METHODS: Testing was conducted at three facilities in two countries (Georgia, Cambodia) using matched fingerstick whole blood, plasma and serum samples. Investigational RDTs were compared with a composite reference standard (CRS) comprised of three laboratory tests, and a reference RDT. RESULTS: In matched samples from 489 HCV positive and 967 HCV negative participants, specificity with both investigational RDTs was high using either reference method (≥98.4% in all sample types). Sensitivity was lower in whole blood versus plasma and serum for both RDTs compared with the CRS (86.5-91.4% vs 97.5-98.0% and 97.3-97.1%) and reference RDT (93.6-97.8% vs 100% and 99.4%). Sensitivity improved when considering only samples with detectable HCV viral load. CONCLUSION: Sensitivity was highest in serum and plasma versus whole blood. The World Health Organization prequalification criterion (≥98%) was narrowly missed by both RDTs in serum, and one in plasma, possibly due to the intended user factor. Performance in whole blood was considered adequate, given potential roles of HCV infection history, improved sensitivity with detectable viral load and performance similarities to the reference RDT.


Asunto(s)
Anticuerpos contra la Hepatitis C/sangre , Hepatitis C/sangre , Adulto , Cambodia , Pruebas Diagnósticas de Rutina , Femenino , Georgia (República) , Hepacivirus/genética , Hepatitis C/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Plasma , Estudios Prospectivos , Estándares de Referencia , Sensibilidad y Especificidad , Pruebas Serológicas/métodos
7.
J Immunol Methods ; 427: 130-3, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26597667

RESUMEN

BACKGROUND: Accidental sample mix-ups and the need for their swift resolution is a challenge faced by every analytical laboratory. To this end, we developed a simple immunoblot-based method, making use of a patient's characteristic plasma antibody profile to Escherichia coli (E. coli) proteins. METHODS: Nitrocellulose strips of size-separated proteins from E. coli whole-cell lysates were incubated with patient plasma and visualised with an enzyme-coupled secondary antibody and substrate. Plasma samples of 20 random patients as well as five longitudinal samples of three patients were analysed for antibody band patterns, to evaluate uniqueness and consistency over time, respectively. For sample mix-ups, antibody band patterns of questionable samples were compared with samples of known identity. RESULTS: Comparison of anti-E. coli antibody patterns of 20 random patients showed a unique antibody profile for each patient. Antibody profiles remained consistent over time, as shown for three patients over several years. Three example cases demonstrate the use of this methodology in mis-labelling or -pipetting incidences. CONCLUSION: Our simple method for resolving plasma sample mix-ups between non-related individuals can be performed with basic laboratory equipment and thus can easily be adopted by analytical laboratories.


Asunto(s)
Anticuerpos Antibacterianos/sangre , Errores Médicos , Western Blotting/métodos , Escherichia coli/inmunología , Hematología/métodos , Humanos , Laboratorios
8.
BMC Infect Dis ; 15: 468, 2015 Oct 29.
Artículo en Inglés | MEDLINE | ID: mdl-26511217

RESUMEN

BACKGROUND: The detection of HIV-1 p24 antigen in diagnostic tests relies on antibodies binding to conserved areas of the protein to cover the full range of HIV-1 subtypes. Using a panel of 43 different virus-like particles (VLPs) expressing Gag from clinical HIV-1 isolates, we previously found that some highly sensitive tests completely failed to detect p24 of certain VLPs, seemingly unrelated to their subtype. Here we aimed to investigate the reason for this failure, hypothesising that it might be due to single amino acid variations in conserved epitopes. METHODS: Using amino acid alignment, we identified single amino acid variations at position 16 or 170 of p24, unique to those VLPs that failed to be detected in certain diagnostic tests. Through DNA-mutagenesis, these amino acids were changed to ones more commonly found at these positions. The impact of these changes on p24 detection was tested in commercial diagnostic tests as well as by Western Blot and ELISA, using epitope-specific antibodies. RESULTS AND CONCLUSIONS: Changing positions 16 or 170 to consensus amino acids restored the detection of p24 by the investigated diagnostic tests as well as by epitope-specific antibodies in Western Blot and ELISA. Hence, single amino acid changes in conserved epitopes can lead to the failure of p24 detection and thus to false-negative results. To optimise HIV diagnostic tests, they should also be evaluated using isolates which harbour less-frequent epitope variants.


Asunto(s)
Aminoácidos , Ensayo de Inmunoadsorción Enzimática/métodos , Proteína p24 del Núcleo del VIH/análisis , VIH-1/aislamiento & purificación , Juego de Reactivos para Diagnóstico , Serodiagnóstico del SIDA/métodos , Aminoácidos/genética , Antígenos Virales/inmunología , Western Blotting , Epítopos/inmunología , Proteína p24 del Núcleo del VIH/genética , Proteína p24 del Núcleo del VIH/inmunología , VIH-1/inmunología , Humanos , Mutagénesis Sitio-Dirigida
9.
PLoS One ; 9(10): e111552, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25343245

RESUMEN

BACKGROUND: Detection of HIV-1 p24 antigen permits early identification of primary HIV infection and timely intervention to limit further spread of the infection. Principally, HIV screening should equally detect all viral variants, but reagents for a standardised test evaluation are limited. Therefore, we aimed to create an inexhaustible panel of diverse HIV-1 p24 antigens. METHODS: We generated a panel of 43 recombinantly expressed virus-like particles (VLPs), containing the structural Gag proteins of HIV-1 subtypes A-H and circulating recombinant forms (CRF) CRF01_AE, CRF02_AG, CRF12_BF, CRF20_BG and group O. Eleven 4th generation antigen/antibody tests and five antigen-only tests were evaluated for their ability to detect VLPs diluted in human plasma to p24 concentrations equivalent to 50, 10 and 2 IU/ml of the WHO p24 standard. Three tests were also evaluated for their ability to detect p24 after heat-denaturation for immune-complex disruption, a pre-requisite for ultrasensitive p24 detection. RESULTS: Our VLP panel exhibited an average intra-clade p24 diversity of 6.7%. Among the 4th generation tests, the Abbott Architect and Siemens Enzygnost Integral 4 had the highest sensitivity of 97.7% and 93%, respectively. Alere Determine Combo and BioRad Access were least sensitive with 10.1% and 40.3%, respectively. Antigen-only tests were slightly more sensitive than combination tests. Almost all tests detected the WHO HIV-1 p24 standard at a concentration of 2 IU/ml, but their ability to detect this input for different subtypes varied greatly. Heat-treatment lowered overall detectability of HIV-1 p24 in two of the three tests, but only few VLPs had a more than 3-fold loss in p24 detection. CONCLUSIONS: The HIV-1 Gag subtype panel has a broad diversity and proved useful for a standardised evaluation of the detection limit and breadth of subtype detection of p24 antigen-detecting tests. Several tests exhibited problems, particularly with non-B subtypes.


Asunto(s)
Antígenos VIH/aislamiento & purificación , Proteína p24 del Núcleo del VIH/metabolismo , Infecciones por VIH/diagnóstico , Juego de Reactivos para Diagnóstico , Proteínas Recombinantes/metabolismo , Virión/metabolismo , Productos del Gen gag del Virus de la Inmunodeficiencia Humana/metabolismo , Secuencia de Aminoácidos , Proteína p24 del Núcleo del VIH/química , Humanos , Datos de Secuencia Molecular , Filogenia , Desnaturalización Proteica
10.
BMC Infect Dis ; 14: 84, 2014 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-24524626

RESUMEN

BACKGROUND: Treatment-naïve patients newly diagnosed with HIV occasionally present with low viral RNA of ≤1'000 copies/ml, raising concerns about viral load underestimation. Because falsely low or undetectable viral loads might lead to inadvertent virus transmission or treatment delays, confirmation of such cases by a sequence-independent viral load test is recommended in Switzerland. METHODS: HIV-1 RNA ≤1'000 cp/ml by Roche's or Abbott's tests in patients newly diagnosed from 2010 to 2012 in Switzerland were subjected to viral load testing by the product-enhanced-reverse transcriptase (PERT) assay. These investigations were complemented with repeat and/or alternative viral RNA measurements. RESULTS: HIV-1 RNA ≤1'000 cp/ml was observed in 71 of 1814 newly diagnosed patients. The PERT assay suggested clinically relevant viral load underestimation in 7 of 32 cases that could be investigated. In four patients, the PERT viral load was 10-1'000-fold higher; this was confirmed by alternative HIV-1 RNA tests. Six of the 7 underestimates had been obtained with meanwhile outdated versions of Roche's HIV-1 RNA test. In the seventh patient, follow-up revealed similar results for RNA and PERT based viral loads. CONCLUSION: PERT assay revealed occasional severe viral load underestimation by versions of HIV-1 RNA tests meanwhile outdated. Underestimation by contemporary tests appears rare, however.


Asunto(s)
Infecciones por VIH/diagnóstico , Transcriptasa Inversa del VIH/química , VIH-1 , Carga Viral , ARN Polimerasas Dirigidas por ADN , Humanos , ARN Viral/análisis , Juego de Reactivos para Diagnóstico , Suiza